ACT Tenancy Compliance Packages
Smoke Alarm Compliance only | Complete Compliance | |
---|---|---|
$75inc GST per year | $99inc GST per year | |
Smoke Alarm Compliance | ||
Replace all faulty or expired smoke alarms | ||
Multiple test for sound, location/ placement, damage | ||
Replace smoke alarm batteries when required | ||
Replace smoke alarm batteries free of charge at change of tenant | ||
No Emergency callout fee | ||
Compliance certificate and audit report showing in detail work done including photos of smoke alarms | ||
Blind Compliance | ||
All window covers inspected | ||
Window clips (cleats) for corded window coverings installed (no extra charges per window cleat or window, unlike other companies*) | ||
Excess or non-compliant cords removed or secured | ||
Safety Switch Testing | ||
Manually trip RCD to ensure its working correctly | ||
Report any faults to Real Estate Agent for rectification | ||
In the event of an RCD fault, after being rectified, we will go out and retest. (no hidden fee for extra call out.) | ||
Air Conditioner Filter Cleaning | ||
Comprehensive dusting of split system and ducted air conditioner intake filters. (does not include evaporative units) | ||
Tax-deductible fee |
ACT Legislation
Smoke Alarm Compliance
- Correct placement, location & number of smoke alarms
- All smoke alarms are not past expiry date (10 years from date of manufacture)
- Alarms tested annually
- Alarms have a decibel reading greater than 85
- New batteries installed every 12 months & with change of tenancy
- A Compliance Certificate/Report is issued annually
Blind Safety Compliance
Window coverings such as curtains, shades and blinds with cords and chains can cause injury and death to young children and babies if they become wrapped around their necks. Strangulation can occur when cords are too long or end in a loop:
Competition And Consumer (corded Internal Window Coverings) Safety Standard 2014.
A corded internal window covering must be installed in such a way that a loose cord cannot form a loop 220 mm or longer, at less than 1,600 mm above floor level.
No part of a cord guide may be installed lower than 1,600 mm above floor level unless the cord guide will remain firmly attached to a wall or other structure specified in the installation instructions when subjected to a tension force of 70 N applied in any direction for 10 seconds; and the cord is sufficiently secured or tensioned to prevent the formation of a loop 220 mm or longer. A cleat used to secure a cord must be installed at least 1,600 mm above floor level.